SOUND INSULATION OF SANDWICH PANELS

Expected parameters for sound insulation of roof and wall coatings, and calculation methods can be determined during design. 

Certain part of sound wave striking to surface reflects, its certain part is absorbed and residue is transmitted. Reflection, absorption and transmission rates depend on surface form, material's sound.

 

CHANGE OF SOUND TRANSMISSION LOSS DEPENDING UPON FREQUENCY (dB)                        

Frequency (Hz)
  125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000
50 mm. 7,3 9,3 11,7 8,5 11,4 12,3 13,3 14,1 14,7 15,9 15,3 11,5 11,8 23,4 29,2 32,4 29,8 32,5 36,9
60 mm. 8,1 22,1 14,2 14,5 13,0 13,9 13,8 14,6 15,3 16,0 15,3 13,0 18,3 24,2 29,2 32,5 29,8 32,5 36,9

 

CHANGE OF SOUND ABSORPTION COEFFICIENT DEPENDING ON FREQUENCY (dB)

                                                                                                                                              

Frequency (Hz)
  315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000
50 mm. 0,08 0,11 0,22 0,2 0,05 0,59 0,09 0,11 0,04 0,07             

0,18

            
0,07
60 mm. 0,14 0,21 0,25 0,25 0,06 0,69 0,12 0,12 0,22 0,08 0,2 0,11